Reliable 10kVA Online Power Backup for Servers, Data Centres and Business-Critical Equipment in Kenya-EVI 10000VA / 10000W Rack Mount Online Single Phase UPS
Protect your business from unexpected power interruptions with the EVI 10000VA / 10000W Rack Mount Online Single-Phase UPS (EP-UPS10000P11OR). Designed for environments where stable, continuous power is essential, this high-capacity uninterruptible power supply delivers up to 10,000VA / 10,000W of rated capacity and uses online double-conversion technology to help protect sensitive electronic equipment from power-related disruptions.
Whether you manage a server room in Nairobi, operate business-critical IT infrastructure, maintain a network operations centre, or need dependable backup for enterprise equipment, the EVI 10kVA online UPS provides a professional power protection solution. Its wide 110–300V AC input range, 1.0 output power factor, built-in lead-acid battery system and external battery connection make it suitable for demanding power backup applications.
With a space-efficient 4U rack-mount design, included tower stands, a 3.5-inch touchscreen and multiple communication interfaces, this EVI UPS is built to fit into modern IT environments while giving administrators convenient access to system information and power management features.
If you are searching for an EVI 10000VA UPS in Kenya, a 10kVA rack mount UPS, or a high-capacity online UPS for servers and network equipment, the EP-UPS10000P11OR is a model worth considering.
Why Choose the EVI EP-UPS10000P11OR 10kVA UPS?
. High 10,000VA / 10,000W Power Capacity
The EVI EP-UPS10000P11OR offers a rated capacity of 10,000VA and 10,000W, with an output power factor of 1.0. This provides a full 10kW of rated real-power capacity, subject to the UPS operating conditions and the connected load.
The capacity makes it a potential fit for organisations protecting multiple IT devices or other compatible equipment from outages and power disturbances. Before purchasing, calculate the total wattage of the equipment you intend to connect and allow appropriate capacity headroom.
Ideal for: server racks, enterprise IT systems, network infrastructure, data storage equipment and other compatible critical electronic loads.
2. Online Double-Conversion Technology for Continuous Power Protection
Power quality matters when servers, storage systems and networking equipment must remain stable. This UPS uses online double-conversion technology, which converts incoming AC power to DC and then regenerates AC output for connected equipment.
This process helps provide consistent output power and reduces the effect of input-voltage fluctuations on supported loads. The specified transfer time between AC mode and battery mode is 0 ms typical, helping keep compatible equipment supplied when mains power fails. The specified inverter-to-bypass transfer time is also 0 ms typical under supported operating conditions.
For businesses that depend on IT systems to serve customers, process transactions or maintain access to critical information, this technology offers an important layer of power continuity.
3. Wide 110–300V AC Input Voltage Range
Power conditions can vary, and an input voltage that fluctuates outside a device’s preferred range can create problems for sensitive equipment. The EVI 10kVA UPS supports a wide stated input voltage range of 110–300V AC, helping it accommodate a broad range of input conditions.
Its input power factor is rated at 0.99 with power factor correction (PFC). This helps improve how effectively the UPS draws power from its supply.
For Kenyan businesses operating offices, server rooms and technical installations, a wide input range can be a useful feature where the incoming supply is not always stable. Actual operation depends on load, input conditions and the manufacturer’s operating limits.
4. Built-In Battery Backup with External Battery Support
The EP-UPS10000P11OR includes 16 × 7Ah sealed lead-acid batteries in a 192V battery system. When mains power fails, the UPS can use its battery system to continue supplying connected equipment for a limited period.
The unit also includes an external battery connector, giving compatible installations a path to additional battery capacity using an approved battery extension system. This is especially relevant for organisations that need to assess or extend backup runtime according to their equipment load and operating requirements.
A maximum charging current of 15A supports battery charging, while the smart battery charging design is intended to optimise battery performance.
Important: Actual backup time depends on the connected load, battery condition, battery configuration and operating environment. If you require a particular runtime, ask your supplier to calculate it for your load before ordering.
5. Flexible Rack-Mount or Tower Installation
The UPS has a 4U rack-mount form factor for installation in a compatible equipment cabinet. Tower-use stands are included, offering another installation option where a rack cabinet is not suitable.
This flexibility can help organisations integrate power protection into existing IT layouts without committing to a single physical arrangement. Before installation, confirm rack depth, mounting support, ventilation, cable access, floor loading and electrical requirements.
The unit is intended for professional installations, so installation and electrical connections should be handled by qualified personnel.
6. Convenient 3.5-Inch Touchscreen Display
The integrated 3.5-inch touchscreen provides an accessible interface for viewing UPS information and navigating supported settings.
For IT administrators and facilities teams, a local display can make routine checks more convenient by providing visibility into system status without relying entirely on remote monitoring software.
Use the display and the manufacturer’s documentation to review available operating information, settings and warnings. Remote monitoring capabilities depend on the interface, supported software and any optional management accessories installed.
7. Communication Ports for Monitoring and Management
The EVI EP-UPS10000P11OR offers multiple communication and control connections for compatible monitoring systems and installation requirements.
Available interfaces and control features include:
- USB: for supported local monitoring or communication.
- RS232: serial communication with compatible systems.
- RS485: serial communication for supported equipment.
- Parallel port: for compatible parallel-system configurations.
- Intelligent card slot: for supported management accessories.
- Programmable dry-contact port: for compatible external signalling and control.
- Maintenance bypass dry contact: for supported maintenance-bypass signalling.
- Emergency Power Off (EPO): for an appropriate emergency shutdown arrangement.
Optional interfaces may be available for specific installations, including a COM port, battery-temperature contact and additional programmable dry contacts. Confirm compatibility and the exact optional accessories required before purchasing.
8. Emergency Power Off for Safety Planning
The built-in Emergency Power Off (EPO) function supports an appropriately designed emergency shutdown arrangement. This can be important in technical rooms and other installations where operators need a defined way to shut down the UPS during an emergency.
EPO wiring and implementation should follow the manufacturer’s instructions and applicable electrical safety requirements. It should not be treated as a substitute for proper site safety procedures.
9. ECO Mode and Generator Compatibility
The UPS supports ECO mode, which can be useful where energy-saving operation is appropriate and the input power quality meets the mode’s requirements. The best operating mode depends on the sensitivity of connected equipment and the priorities of the installation.
Generator compatibility also makes the unit a candidate for installations that use a generator as part of their backup-power arrangement. Generator and UPS settings should be checked for compatibility, including voltage, frequency, capacity and load characteristics.
10. Flexible Output Voltage Selection
The EVI 10kVA online UPS supports selectable output voltages of:
- 200V AC
- 208V AC
- 220V AC
- 230V AC
- 240V AC
This range gives installers flexibility to match supported equipment and site requirements. The output voltage should be selected by a qualified installer based on the equipment specifications and electrical installation.
11. Dedicated C19 and C13 Output Sockets
The unit is specified with two C19 outlets and three C13 outlets. These connector types are commonly used in IT power distribution, but the correct power cables and connections depend on the equipment being supplied.
Check the input connectors, power requirements and cable ratings of your servers, switches, storage devices and other equipment before connecting them. For larger installations, a compatible power distribution unit (PDU) may be required.
Recommended Applications of the EVI 10kVA Online UPS
The EVI EP-UPS10000P11OR can be considered for a range of professional power-protection applications, provided the connected load is within its supported ratings.
- Server rooms and data centres: Help maintain power to compatible servers, storage systems and related infrastructure during mains interruptions.
- Corporate offices: Support continuity for critical IT equipment used in daily business operations.
- Networking infrastructure: Provide backup power for compatible network switches, routers, security appliances and other essential network devices.
- IT service providers: Add a dedicated power-protection layer to installations that host business systems or support customers’ technical operations.
- Commercial and technical facilities: Protect compatible electronic equipment where power continuity and controlled shutdown are important.
- Generator-backed installations: Work as part of a professionally designed backup-power arrangement when the generator and UPS are correctly configured.
- The UPS should be selected according to the equipment’s actual power consumption, startup characteristics, required backup duration and installation requirements.